SEHI-22, SEHI-24, SEHI-32, AND SEHI-3410BASE-T INTELLIGENT STACKABLE HUBUSER’S GUIDE CABLETRON SYSTEMS, P. O. Box 5005, Rochester, NH 03867-0505The C

Pagina 2 - Recycled Pa

INTRODUCTION Page 1-2 1.2 GETTING HELP If you need additional support related to the Cabletron Systems SEHI, or if you have any questions, comments,

Pagina 3

INTRODUCTION Page 1-3The SEHI-22/24 and SEHI-32/34 are functionally identical with the exception of the network ports:• SEHI-22 , 12 RJ45 network por

Pagina 4

INTRODUCTION Page 1-4 LANVIEW LEDs Cabletron Systems’ LANVIEW Status Monitoring and Diagnostics System is a troubleshooting tool that helps you diag

Pagina 5

INTRODUCTION Page 1-5 1.7 OPTIONAL FEATURES The following features are not included with the SEHI but can be purchased separately from Cabletron Syst

Pagina 6 - TABLE OF CONTENTS

INTRODUCTION Page 1-6 Daughter Board Upgrade Kit You can upgrade the SEHI-22 and the SEHI-32 to 24 ports using the daughter board upgrade kit. The Ca

Pagina 7

INSTALLATION REQUIREMENTS/SPECIFICATIONS Page 2-1 CHAPTER 2INSTALLATIONREQUIREMENTS/SPECIFICATIONS This Chapter describes cabling requirements, netwo

Pagina 8

INSTALLATION REQUIREMENTS/SPECIFICATIONS Page 2-2 2.1.2 UTP and STP Cable Specifications for the Network Portsand EPIM-T Module The device at the othe

Pagina 9 - INTRODUCTION

INSTALLATION REQUIREMENTS/SPECIFICATIONS Page 2-3 Delay The maximum propagation delay of a 10BASE-T link segment must not exceed 1000 nsec. This 1000

Pagina 10 - OUT

INSTALLATION REQUIREMENTS/SPECIFICATIONS Page 2-4 2.1.3 Multimode Fiber Optic Cable Specifications for theEPIM-F1 and EPIM-F2 ModulesTable 2-1 shows M

Pagina 11

INSTALLATION REQUIREMENTS/SPECIFICATIONSPage 2-52.1.4 Single Mode Fiber Optic Cable Specifications forthe EPIM-F3 ModuleTable 2-2 shows Single Mode Fib

Pagina 12

NOTICE i NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior

Pagina 13

INSTALLATION REQUIREMENTS/SPECIFICATIONSPage 2-62.1.5 Thin-Net Network Requirements for the EPIM-C ModuleWhen you connect a thin-net segment to the SE

Pagina 14

INSTALLATION REQUIREMENTS/SPECIFICATIONSPage 2-72.1.6 AUI Cable Requirements for the EPIM-Aand EPIM-X ModulesWhen you connect an external network segm

Pagina 15 - REQUIREMENTS/SPECIFICATIONS

INSTALLATION REQUIREMENTS/SPECIFICATIONSPage 2-82.2.1 SEHI-22 and SEHI-24 Network Port SpecificationsThe SEHI-22 and SEHI-24 provide RJ45 connections f

Pagina 16

INSTALLATION REQUIREMENTS/SPECIFICATIONSPage 2-9Table 2-3. Champ Connector Pinouts50 Pin Champ ConnectorPin Signal Wire Color Pin Signal Wire Color1 R

Pagina 17

INSTALLATION REQUIREMENTS/SPECIFICATIONSPage 2-102.3 EPIM SPECIFICATIONSEPIMs let you connect the SEHI to the main network using different media types

Pagina 18

INSTALLATION REQUIREMENTS/SPECIFICATIONSPage 2-112.3.2 EPIM-F1 and EPIM-F2 The EPIM-F1 and EPIM-F2 shown in Figure 2-4 support Multimode Fiber Optic c

Pagina 19

INSTALLATION REQUIREMENTS/SPECIFICATIONSPage 2-122.3.3 EPIM-F3The EPIM-F3 shown in Figure 2-5 supports Single Mode Fiber Optic cabling. It has an inte

Pagina 20

INSTALLATION REQUIREMENTS/SPECIFICATIONSPage 2-13Parameter Typical Minimum MaximumTransmitter Peak Wave Length 1300 nm 1270 nm 1330 nmSpectral Width 6

Pagina 21

INSTALLATION REQUIREMENTS/SPECIFICATIONSPage 2-142.3.4 EPIM-CThe EPIM-C supports thin-net coaxial cabling and is equipped with an internal Cabletron S

Pagina 22 - 1 2 3 4 5 6 7 8

INSTALLATION REQUIREMENTS/SPECIFICATIONSPage 2-152.3.5 EPIM-A and EPIM-X (AUI Port)The EPIM-A is a DB15 female connector used to attach segments to an

Pagina 23

NOTICE ii FCC NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may no

Pagina 24

INSTALLATION REQUIREMENTS/SPECIFICATIONSPage 2-162.4 COM PORT REQUIREMENTSThe RJ45 COM port supports access to a Local Management Console. The Console

Pagina 25

INSTALLATION REQUIREMENTS/SPECIFICATIONSPage 2-172.6 OPERATING SPECIFICATIONSThe operating specifications for the SEHI are described in this section. C

Pagina 26

INSTALLATION REQUIREMENTS/SPECIFICATIONSPage 2-18JAM Output: Collisions are propagated through the network using the JAM signal of an alternating patt

Pagina 27

INSTALLATION REQUIREMENTS/SPECIFICATIONSPage 2-19ENVIRONMENTAL REQUIREMENTSOperating Temperature: +5° to +50° CNon-operating Temperature: -30° to +90°

Pagina 28 - Internal Termination Switch

INSTALLATIONPage 3-1CHAPTER 3INSTALLATIONThis chapter outlines the procedure for installing the SEHI to your network as a stackable or stand-alone dev

Pagina 29

INSTALLATIONPage 3-2Free-standing and shelf installations must be within in reach of the network cabling and meet the requirements listed below:• A si

Pagina 30

INSTALLATIONPage 3-3To stack the SEHI together with an SEH non-intelligent hub:1. Attach the SEHI HubSTACK Interconnect cable to the “OUT” port on the

Pagina 31

INSTALLATIONPage 3-4If you disconnect one end of a HubSTACK Interconnect cable and leave the other end attached to the hub, ensure that you disconnect

Pagina 32

INSTALLATIONPage 3-53.2.3 Rack Mounting the SEHIRefer to Figure 3-4 and perform these steps to install the SEHI in a 19-inch rack.1. Remove four cover

Pagina 33

INSTALLATIONPage 3-63.2.4 Wall Mounting the SEHIWhen you wall mount the SEHI, the cable connections must face down. Refer to Figure 3-6 and perform th

Pagina 34 - CHAPTER 3

NOTICE iii CABLETRON SYSTEMS, INC.PROGRAM LICENSE AGREEMENT IMPORTANT: Before utilizing this product, carefully read this License Agreement.This doc

Pagina 35

INSTALLATIONPage 3-73. You will need a pencil for this step. With the wall mounting brackets attached to the SEHI, position the SEHI against the wall

Pagina 36 - WITH LANVIEW®

INSTALLATIONPage 3-83.3 CONNECTING THE SEHI TO THE POWER SOURCENote: The SEHI has a universal power supply. This allows you to connect the SEHI to pow

Pagina 37

CONNECTING TO THE NETWORKPage 4-1CHAPTER 4CONNECTING TO THE NETWORKThis chapter outlines the procedure for connecting the SEHI to your network. Ensure

Pagina 38 - 19-Inch Rack

CONNECTING TO THE NETWORKPage 4-2To connect twisted pair segments to the SEHI:1. Insert the RJ45 connector from each twisted pair segment into the des

Pagina 39 - Bracket Screws

CONNECTING TO THE NETWORKPage 4-34.1.2 Connecting to Network Ports, SEHI-32 and SEHI-34The SEHI-32 has a 50-pin Champ connector, while the SEHI-34 has

Pagina 40 - 10BASE-T HUB WITH LANVIEW®

CONNECTING TO THE NETWORKPage 4-44. Check that the link LED on the 10BASE-T Ethernet device and the applicable LNK LED on the SEHI are on. If the LEDs

Pagina 41

CONNECTING TO THE NETWORKPage 4-5To connect an EPIM-T to a Twisted Pair Segment:1. Insert the RJ45 connector on the twisted pair segment into the RJ45

Pagina 42 - CONNECTING TO THE NETWORK

CONNECTING TO THE NETWORKPage 4-6• The physical communication link consists of two strands of fiber optic cabling: the Transmit (TX) and the Receive (R

Pagina 43

CONNECTING TO THE NETWORKPage 4-7Figure 4-4. The EPIM-F1, EPIM-F2 and EPIM-F33. Attach the fiber labeled 2 to the applicable transmit port labeled TX,

Pagina 44

CONNECTING TO THE NETWORKPage 4-86. Check that the EPIM’s LNK LED is on. If the LED is not on, perform the following steps until it is:a. Check that t

Pagina 45

NOTICE iv EXCLUSION OF WARRANTYAND DISCLAIMER OF LIABILITY 1. EXCLUSION OF WARRANTY. Except as may be specifically provided by Cabletron in writing,

Pagina 46

CONNECTING TO THE NETWORKPage 4-9Note: You must terminate each segment attached to the tee-connector. If you do not attach a segment to one of the fem

Pagina 47

CONNECTING TO THE NETWORKPage 4-104.1.6 Connecting an AUI Cable to an EPIM-ACaution: Ensure that the external transceiver to which the SEHI will be co

Pagina 48

CONNECTING TO THE NETWORKPage 4-115. Check that the PWR LED on the EPIM-A is on. If the LED is not on, contact Cabletron Systems Technical Support.6.

Pagina 49

CONNECTING TO THE NETWORKPage 4-12Figure 4-7. The EPIM-X4.2 FINISHING THE INSTALLATIONThe SEHI is now ready for operation. Before placing the network

Pagina 50

TROUBLESHOOTINGPage 5-1CHAPTER 5TROUBLESHOOTINGThis chapter contains instructions for using LANVIEW LEDs to troubleshoot physical layer network proble

Pagina 51

TROUBLESHOOTINGPage 5-22. If the remote station is ready and the LNK LED is on, but no data passes through the port, one of two conditions may exist:•

Pagina 52

TROUBLESHOOTINGPage 5-3Figure 5-1. LANVIEW LEDsPWR When this green LED is on it indicates that the SEHI is receiving power. If this LED is not on, it

Pagina 53

TROUBLESHOOTINGPage 5-4CLNThis red LED indicates that a collision has occurred on one of the ports.RCV When this yellow LED flashes, it indicates that

Pagina 54 - TROUBLESHOOTING

LOCAL MANAGEMENTPage 6-1CHAPTER 6LOCAL MANAGEMENTThis chapter explains how to set up a management terminal to access the SEHI’s Local Management. It a

Pagina 55

LOCAL MANAGEMENTPage 6-26.1 MANAGEMENT TERMINAL REQUIREMENTSTo access Local Management you need one of the following:• a Digital Equipment Corporation

Pagina 56 - 10BASE-T HUB WITH LANVIEW®

CONTENTS v TABLE OF CONTENTS APPENDIX A TABLE OF CONTENTS vCHAPTER 1 INTRODUCTION 1.1 USING THIS MANUAL...

Pagina 57

LOCAL MANAGEMENTPage 6-36.1.1 Console Cable ConfigurationUse the RJ45 Cable Kit provided with the SEHI-ACCY-KIT package to attach the management termin

Pagina 58 - LOCAL MANAGEMENT

LOCAL MANAGEMENTPage 6-46.1.2 Management Terminal Setup ParametersTable 6-1 lists the setup parameters for the local management terminal. If your term

Pagina 59

LOCAL MANAGEMENTPage 6-56.2 ACCESSING LOCAL MANAGEMENTAfter you configure the local management terminal and properly attach the cables to the SEHI, you

Pagina 60 - LANVIEW®

LOCAL MANAGEMENTPage 6-63. Press the Return key.• If your password entry is invalid, the cursor returns to the beginning of the password entry field.•

Pagina 61

LOCAL MANAGEMENTPage 6-76.3 USING THE LOCAL MANAGEMENT SCREENSThe Feature Selection screen is the main menu screen for SEHI Local Management. You can

Pagina 62

LOCAL MANAGEMENTPage 6-8The Community Name Table option lets you set community names. Community names are passwords to Local Management and they are a

Pagina 63

LOCAL MANAGEMENTPage 6-9Editing the Community Name FieldThe password that you use to access Local Management at the Password screen must have Super-Us

Pagina 64

LOCAL MANAGEMENTPage 6-106.3.2 The Configuration ScreenTo access the Configuration screen from the Feature Selection screen, use the arrow keys to highl

Pagina 65

LOCAL MANAGEMENTPage 6-11SubNet MaskDisplays the subnet mask for the SEHI. A subnet mask is a 32-bit quantity which “masks out” the network bits of th

Pagina 66

LOCAL MANAGEMENTPage 6-124. Use the arrow keys to highlight the SAVE option, then press the Return key or F6. The “SAVED OK” message appears indicatin

Pagina 67

CONTENTS vi2.6 OPERATING SPECIFICATIONS...2-17 CHAPTER 3 INSTALLATION 3.1 UNPACKING THE SEHI ...

Pagina 68

LOCAL MANAGEMENTPage 6-13Setting the Default GatewayThe Default Gateway field allows you to describe the router through which the SEHI will be forwardi

Pagina 69

LOCAL MANAGEMENTPage 6-14Exiting the Configuration Screen1. To exit the Configuration screen, press the appropriate Function key. To return to the Fea

Pagina 70

LOCAL MANAGEMENTPage 6-15SNMP Community NameDisplays the community name to be included in the trap message, which is sent to the Network Management St

Pagina 71

LOCAL MANAGEMENTPage 6-16Exiting the Trap Table Screen1. To exit the Trap Table screen, press the appropriate Function key. To exit to the Feature Sel

Pagina 72

LOCAL MANAGEMENTPage 6-17Figure 6-7. SNMP Tools ScreenThe following sections describe SNMP Tools screen fields and instructions on how to change them.C

Pagina 73

LOCAL MANAGEMENTPage 6-18WalkScrolls you through a section of the MIB leaf by leaf, from a user-specified object identifier. Leaves are the sections of

Pagina 74

LOCAL MANAGEMENTPage 6-19Getting Individual OIDsTo get an OID:1. Highlight GET, using the arrow keys, then press the Return key (or press the F6 funct

Pagina 75

LOCAL MANAGEMENTPage 6-20Setting an OIDTo set an OID:1. Highlight SET, using the arrow keys, then press the Return key (or press the F7 function key).

Pagina 76

LOCAL MANAGEMENTPage 6-21Walking Through OIDsTo walk through an OID:1. Highlight Walk, using the arrow keys, then press the Return key. “<INITIAL&g

Pagina 77

LOCAL MANAGEMENTPage 6-22Exiting the SNMP Tools Screen1. Use the arrow keys to highlight the RETURN command.2. Press the Return key. The Feature Selec

Pagina 78

CONTENTS vii APPENDIX B TWISTED PAIR WIRING TABLES A-1

Pagina 79

LOCAL MANAGEMENTPage 6-23Bytes ReceivedDisplays the number of bytes received.Frames ReceivedDisplays the number of frames received.Errors ReceivedDisp

Pagina 80

LOCAL MANAGEMENTPage 6-24Port Seg. StatusDisplays the segmentation status of the port selected. The two possible status messages are Segmented or Unse

Pagina 81

LOCAL MANAGEMENTPage 6-25Selecting the Appropriate Module/PortWhen the Device Statistics screen first appears, statistics are displayed for Module 1 an

Pagina 82

LOCAL MANAGEMENTPage 6-26Using the Disable Port CommandThe Disable Port command lets you Disable the port selected in the Port command. You must first

Pagina 83

TWISTED PAIR WIRING TABLESPage A-1APPENDIX ATWISTED PAIR WIRING TABLESThis appendix contains twisted pair wiring tables which will assist you if you a

Pagina 84 - TWISTED PAIR WIRING TABLES

Page A-2TWISTED PAIR WIRING TABLESNote: Pins 25 and 50 on Champ connector are not used.Table A-1. Twisted Pair Wiringfrom an SEHI-32/34 to a Punch Dow

Pagina 85

TWISTED PAIR WIRING TABLESPage A-3Port 8/20Pin Pin PinRX+ 40 40 Black/Gray RX+ A29 Black/Gray RX+RX- 15 15 Gray/Black RX- A30 Gray/Black RX-TX+ 41 41

Pagina 86

Page A-4TWISTED PAIR WIRING TABLESPort 4/16Pin Pin PinRX+ 32 32 Red/Orange RX+ A13 Red/Orange RX+RX- 7 7 Orange/Red RX- A14 Orange/Red RX-TX+ 33 33 Re

Pagina 87

TWISTED PAIR WIRING TABLESPage A-5Table A-2. Twisted Pair Wiringfrom a Punch Down Block to a 10Base-T Device From Punch Down BlockTo RJ-45 WallplateIn

Pagina 88

Page A-6TWISTED PAIR WIRING TABLESPort 8/20 Pin Pin PinB29 Black/Gray RX+ 1 TX+ 1 TX+ 1 TX+B30 Gray/Black RX- 2 TX- 2 TX- 2 TX-B31 Yellow/Blue TX+ 3 R

Pagina 89

INTRODUCTION Page 1-1 CHAPTER 1INTRODUCTION Welcome to the Cabletron Systems SEHI-22, SEHI-24, SEHI-32, and SEHI-34 10BASE-T Intelligent Stackable H

Pagina 90

TWISTED PAIR WIRING TABLESPage A-7Port 4/16 Pin Pin PinB13 Red/Orange RX+ 1 TX+ 1 TX+ 1 TX+B14 Orange/Red RX- 2 TX- 2 TX- 2 TX-B15 Red/Green TX+ 3 RX+

Pagina 91

Page A-8TWISTED PAIR WIRING TABLESTable A-3. Twisted Pair Wiring SummarySEHI-32/34 ChampPunch Down BlockWall Plate(If Required) 10BASE-T Ethernet Devi

Pagina 92 - Figure A-1. Punch Down Block

TWISTED PAIR WIRING TABLESPage A-9Figure A-1. Punch Down Block1234567891011121314151617181920212223242526272829303132333435363738394041424344454647484

Pagina 93

POWER SUPPLY CORDThe mains cord used with this equipment must be a 2 conductor plus ground type with minimum 0.75 mm square conductors and must incorp